Skip to main content Skip to search Skip to main navigation
Your online store for tubes & electronic components of all kinds reliable and fast – since 1946
Prices shown incl. VAT for Germany. Select your delivery country for accurate pricing.

Tung-Sol 6V6GT – BTB-matched pair for Tweed, hi-fi and guitar amplifiers

This set contains two current-production Tung-Sol 6V6GT beam power tetrodes. Each valve uses an eight-pin octal base, a nominal 6.3 V heater and carries a maximum plate-dissipation rating of 13.2 W.

BTB matches both output valves at a practical plate voltage of 400 V. The pair is suitable for compatible push-pull stages using two 6V6GT valves or two identically configured single-ended channels.

Suitable applications

  • Tweed and Deluxe-style guitar amplifiers using two 6V6GT valves
  • Hi-fi push-pull stages using one 6V6GT pair
  • Stereo single-ended amplifiers using one 6V6GT per channel
  • Complete replacement of an existing two-valve 6V6GT set
  • New builds with a correctly rated output transformer
  • Amplifiers whose plate and screen-grid voltages suit the current version

BTB matching and package contents

Package contents
Two Tung-Sol 6V6GT valves
Selection type
BTB-matched pair
Matching plate voltage
A practical 400 V unless the specific product states otherwise
Test system
Roetest V11, current as of 2026
Parameters considered
Plate current, transconductance, grid currents, plate resistance and acoustic checks
5992 designation
BTB search and article wording; not confirmed as the current type designation in the manufacturer's data sheet

Technical data

Valve type
Beam power tetrode
Type designation
6V6GT Tung-Sol
Base
Eight-pin octal
Heater voltage
6.3 V nominal
Heater current
460 to 530 mA per valve
Data-sheet test point
250 V plate and screen-grid voltage with -12.5 V control-grid voltage
Plate current at the test point
33 to 59 mA
Screen-grid current at the test point
8 mA maximum
Transconductance at the test point
3 to 5.2 mA/V
Single-ended output example
At least 3.2 W into a 5 kΩ plate load under the stated conditions
Maximum plate voltage
350 V according to the current production sheet
Maximum screen-grid voltage
310 V
Maximum plate dissipation
13.2 W
Maximum screen-grid dissipation
2.2 W
Dimensions
Approximately 87 ±2 mm overall height and 29.6 mm maximum envelope diameter
Country of origin
Russia according to current BTB and manufacturer information

Pinout

Pins 1 and 6
No internal electrode connection according to the current data sheet
Pins 2 and 7
Heater
Pin 3
Plate
Pin 4
Screen grid g2
Pin 5
Control grid g1
Pin 8
Cathode and beam-forming plates

Comparison with 6V6GTA and historical 5992 types

Tung-Sol 6V6GT
Current production designation of the offered valve
6V6GTA
Historically related version with potentially additional warm-up or equipment requirements
5992
Historical special or quality designation that must not be applied to every current 6V6GT without a clear manufacturer specification

Selection and application notes

Matching does not replace bias or operating-point verification. Set the bias in a fixed-bias circuit; in a cathode-biased circuit, check cathode voltage and plate dissipation.

Some guitar amplifiers operate 6V6 valves above classic data-sheet voltages. A manufacturer description of rugged guitar use does not replace measurement of the plate voltage, screen voltage and dissipation.

The manufacturer's approximately 87 mm overall height must be considered in compact combos, valve retainers and enclosure covers.

Power valves operate with lethal voltages and become very hot. Installation and measurements require suitable expertise.

Questions about selection and use

Is the Tung-Sol 6V6GT BTB-matched pair suitable for a push-pull stage using two 6V6 valves?

Yes, the Tung-Sol 6V6GT BTB-matched pair is suitable for compatible push-pull stages using a total of two 6V6GT valves. The heater supply, plate and screen-grid voltages, bias, output transformer and height must suit the circuit.

Can the Tung-Sol pair replace an existing two-valve 6V6GT set?

Yes, the Tung-Sol pair can replace an existing two-valve 6V6GT set when the base, operating point, heater demand and mechanical clearance match. The BTB wording 5992 does not constitute a separate current manufacturer approval.

Should the operating point be checked after installing the matched 6V6GT pair?

Yes, the operating point must be checked after installation. Adjust the bias in a fixed-bias amplifier; in a cathode-biased amplifier, verify cathode current, plate dissipation, screen-grid loading and heater voltage.

Note: All brand names mentioned, such as Marshall, Fender, etc., are registered trademarks of their respective owners and are used here for descriptive and compatibility purposes only.

Responsible(EU)
BTB Elektronik Vertriebs GmbH Kepler Strasse 6
DE-90766 Fürth
Email: info@btb-elektronik.de
pdf
Title: 1-EN-GPSR.pdf Filesize: 250,86 KB

The EU Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (2011/65/EU = "RoHS 2") aims to exclude certain hazardous substances from electrical and electronic equipment or to restrict the use of certain substances in electrical and electronic equipment. These include substances such as lead, mercury, cadmium, and chromium, as well as certain brominated flame retardants and plasticizers. These substances may only be used in electrical and electronic equipment up to a maximum concentration limit, unless exemptions in the annexes to the directive permit their use under certain conditions. This can reduce and eliminate harmful substances and improve the recycling of waste electrical and electronic equipment. To find out whether the component you purchased from us is permitted in your device, please refer to the current directive or the current law applicable to your country. If you are a manufacturer, please feel free to contact us to find out whether the component you require can be tested and approved according to the current directives. We would be happy to assist you.

Fact sheet on EU Directive 2011/65/EU
Restriction of the use of hazardous substances in electrical and electronic equipment (PDF, not accessible, 2 MB)

Implementation of the RoHS Directive:
https://environment.ec.europa.eu/topics/waste-and-recycling/rohs-directive/implementation-rohs-directive_en

Source: IHK Mittelfranken

This product is: RoHS konform

Tariff Number: 85408100

Country of Origin: RU