Skip to main content Skip to search Skip to main navigation
Your online store for tubes & electronic components of all kinds reliable and fast – since 1946

Lundahl LL1693/PP – high-power push-pull output transformer for low-impedance valve stages

The Lundahl LL1693/PP is a large push-pull output transformer for low-impedance, high-current output valves. It provides plate-to-plate loads of approximately 600 Ω, 1 kΩ or 2.3 kΩ.

Two five-section coils, a grain-oriented silicon-steel C-core and a small balancing air gap support substantial signal current and low leakage. Typical design starting points include 6C33C, 6336, 6528A and correctly designed parallel push-pull stages.

Suitable applications

  • Push-pull output stages using 6C33C-B or 6S33S valves
  • 6336, 6528A and related low-impedance high-current triode stages
  • Parallel push-pull circuits using several output valves per channel
  • Plate-to-plate loads of 600 Ω, 1 kΩ or 2.3 kΩ
  • 4, 8 and 16 Ω loudspeakers with the documented secondary connection
  • Class A and Class AB1 amplifiers using a sufficiently capable driver and power supply

Technical data

Product type
High-power push-pull valve output transformer
Model version
LL1693/PP
Primary impedances
Approx. 600 Ω, 1 kΩ or 2.3 kΩ plate-to-plate
Secondary impedances
4, 8 or 16 Ω, depending on the primary load and secondary connection
Turns ratio
8+7+1+8+7+1:1+1+1+1+1+1+1+1
Push-pull balancing air gap
Approx. 25 µm
Primary inductance
Approx. 150 H
Primary DC resistance
Approx. 60 Ω with all primary sections in series
Secondary DC resistance
Approx. 0.4 Ω for inner and 0.5 Ω for outer sections
Thermal primary-current limit
450 mA according to the 12 W winding-loss criterion; not a permitted DC imbalance
Permitted DC imbalance
No universal numerical value is stated in the manufacturer data sheet
Maximum primary signal voltage in PP operation
Approx. 530 V RMS at 30 Hz
Magnetic power limit at 2.3 kΩ
Approx. 180 W at 30 Hz in push-pull operation
Magnetic power limit at 1 kΩ
Approx. 360 W at 30 Hz in push-pull operation
Magnetic power limit at 600 Ω
Approx. 700 W at 30 Hz in push-pull operation
Interpretation of power figures
Magnetic transformer limits rather than guaranteed complete-amplifier output
Core material
Grain-oriented silicon-steel C-core
Winding construction
Two coils, each divided into five sections
Primary-to-secondary isolation
To be considered according to the exact manufacturer drawing and complete equipment safety design
Dimensions
Approx. 140 × 100 × 100 mm
Mounting pattern
Approx. 58 × 118 mm with four M4 mounting points
Weight
Approx. 4.5 kg
Country of origin
Sweden

Primary loads and loudspeaker matching

2.3 kΩ plate-to-plate
8 Ω using secondary Alternative B or 16 Ω using Alternative C; no documented standard 4 Ω connection
1 kΩ plate-to-plate
4 Ω using Alternative B, 8 Ω using Alternative C or 16 Ω using Alternative D
600 Ω plate-to-plate
4 Ω using Alternative C, 8 Ω using Alternative D or 16 Ω using Alternative E
Selection rule
Determine the plate-to-plate load from valve count, plate and screen voltage, quiescent current, operating class and required output before selecting the secondary connection

Quiescent-current balance and parallel push-pull

The 25 µm balancing air gap increases tolerance of minor quiescent-current imbalance. It does not replace valve matching or individual bias adjustment and does not permit arbitrary differential current between the primary halves.

Where several valves operate in parallel, each valve should have an individual control-grid stopper and, for screen-grid valves, normally an individual screen-grid stopper. Plate, grid and cathode wiring should be as symmetrical as practical.

Verify the current of every output valve individually. The 450 mA thermal figure does not define the permitted magnetic imbalance of the push-pull stage.

Power and safety notes

The high 30 Hz power figures describe magnetic transformer headroom only. The valves, power supply, driver stage, operating class, plate dissipation and cooling determine actual amplifier output.

The LL1693 can carry substantial voltage and current. Install it in a closed, touch-safe enclosure on a chassis capable of supporting 4.5 kg plus transport loading.

Questions about selection and use

Which push-pull output transformer suits low-impedance 6C33C, 6336 or 6528A output stages?

Lundahl LL1693/PP provides 600 Ω, 1 kΩ and 2.3 kΩ plate-to-plate loads for correctly designed high-current push-pull stages. Valve count, supply voltage, quiescent current and operating class determine the appropriate load.

Which Lundahl high-power transformer provides 600 Ω, 1 kΩ and 2.3 kΩ plate-to-plate loads?

Lundahl LL1693/PP is officially documented with these three primary loads. The BTB title values of 150 and 300 Ω are not standard loads in the manufacturer data sheet.

Can the LL1693/PP be matched to 4, 8 and 16 Ω loudspeakers?

Yes, the LL1693/PP can be matched to 4, 8 or 16 Ω depending on the selected primary load. The standard 2.3 kΩ connection provides 8 and 16 Ω alternatives.

Is the 25 µm balancing air gap intended for small quiescent-current imbalance?

Yes, the 25 µm air gap improves tolerance of minor DC imbalance. Lundahl does not state a universal maximum differential current, so valve matching and bias verification remain necessary.

Note: All brand names mentioned, such as Marshall, Fender, etc., are registered trademarks of their respective owners and are used here for descriptive and compatibility purposes only.

pdf
Title: Ar4C4C313639332F50502041DC_LL1693_PP_BTB.pdf Filesize: 67,76 KB
Responsible(EU)
Lundahl Transformers AB
SE-76150 Norrtälje
Email: order@lundahltransformers.com
pdf
Title: -EN-GPSR.pdf Filesize: 254,48 KB

The EU Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (2011/65/EU = "RoHS 2") aims to exclude certain hazardous substances from electrical and electronic equipment or to restrict the use of certain substances in electrical and electronic equipment. These include substances such as lead, mercury, cadmium, and chromium, as well as certain brominated flame retardants and plasticizers. These substances may only be used in electrical and electronic equipment up to a maximum concentration limit, unless exemptions in the annexes to the directive permit their use under certain conditions. This can reduce and eliminate harmful substances and improve the recycling of waste electrical and electronic equipment. To find out whether the component you purchased from us is permitted in your device, please refer to the current directive or the current law applicable to your country. If you are a manufacturer, please feel free to contact us to find out whether the component you require can be tested and approved according to the current directives. We would be happy to assist you.

Fact sheet on EU Directive 2011/65/EU
Restriction of the use of hazardous substances in electrical and electronic equipment (PDF, not accessible, 2 MB)

Implementation of the RoHS Directive:
https://environment.ec.europa.eu/topics/waste-and-recycling/rohs-directive/implementation-rohs-directive_en

Source: IHK Mittelfranken

This product is: RoHS konform

Tariff Number: 85043129

Country of Origin: SE