Lundahl LL1941 high-ratio transformer for low-output MC cartridges

The Lundahl LL1941 is a premium high-ratio step-up transformer for particularly quiet and low-impedance moving-coil cartridges. Its 1:16 and 1:32 ratios provide approximately 24 or 30 dB of passive voltage gain.

An amorphous cobalt core, Cardas OFC windings, dual-coil construction and a mu-metal enclosure make it especially attractive for Ortofon SPU, Cadenza and Quintet models, Dynavector, Phasemation and other low-output cartridges.

Suitable applications

  • Ortofon SPU Classic G and GE MkII at 1:32
  • Ortofon Cadenza and Quintet at 1:16
  • Dynavector 20X2A-L, XX-2A and Phasemation PP cartridges
  • Very low-output MC cartridges feeding an MM phono stage

Technical specifications

Transformer type
Premium low-output MC step-up transformer, one channel per component
Core material
Uncut amorphous cobalt strip core
Winding wire
Cardas high-purity OFC copper
Winding construction
Symmetrical dual-coil structure in a mu-metal enclosure
Step-up ratios
1:16 or 1:32
Voltage gain
Approximately 24.1 dB at 1:16 or 30.1 dB at 1:32
Cartridge load with a 47 kΩ MM input
Approximately 184 Ω at 1:16 or 46 Ω at 1:32 without additional loading
Data-sheet frequency response
Approximately 10 Hz to 100 kHz within ±1 dB using a 10 Ω source and open secondaries
Dimensions
Approximately 43 × 29 × 22 mm
Weight
Approximately 90 g
Stereo requirement
Two LL1941 transformers are required for stereo

Choosing 1:16 or 1:32

A 1:16 ratio is often the more balanced starting point for cartridges producing approximately 0.25 to 0.4 mV. The 1:32 ratio is particularly useful around 0.1 to 0.2 mV, provided that the cartridge accepts the lower reflected load and the MM stage can accommodate approximately 30 dB of passive gain.

A high turns ratio is not automatically correct for every low-impedance cartridge. A design combining unusually high output with a high recommended load may require a lower ratio despite having a very low internal impedance.

Questions about choosing a low-output MC transformer

Which transformer suits an Ortofon SPU Classic G or GE MkII?

The Lundahl LL1941 at 1:32 is a particularly suitable starting point. A 0.2 mV cartridge output becomes approximately 6.4 mV, while a 47 kΩ MM input reflects about 46 Ω to the 2 Ω cartridge. A 1:16 connection producing approximately 3.2 mV may be better for a sensitive MM stage.

Which step-up transformer suits an Ortofon Cadenza, Quintet or Dynavector XX-2A?

The LL1941 can initially be connected at 1:16. A Cadenza Bronze then produces approximately 6.4 mV, a Quintet about 4.8 mV and a Dynavector XX-2A approximately 4.5 mV. The reflected load from a 47 kΩ input is about 184 Ω.

Can I select either 1:16 or 1:32 with the LL1941?

Yes, both ratios are available through different external winding connections. A ratio selector may be added when signal paths remain very short, high-quality contacts are used and the wiring follows the Lundahl data sheet exactly.

Is the LL1941 suitable for a Phasemation PP-1000, PP-2000 or PP-5000?

Yes, these approximately 0.3 mV, 4 Ω cartridges can be used at 1:16 and then produce about 4.6 to 4.8 mV. A 1:32 ratio produces roughly 9.3 to 9.6 mV and should only be used with sufficient MM-stage headroom and suitable cartridge loading.

Note: All brand names mentioned, such as Marshall, Fender, etc., are registered trademarks of their respective owners and are used here for descriptive and compatibility purposes only.

pdf
Title: ArLL1941_LL1941.pdf Filesize: 38,58 KB
Responsible(EU)
Lundahl Transformers AB
SE-76150 Norrtälje
Email: order@lundahltransformers.com
pdf
Title: -EN-GPSR.pdf Filesize: 254,48 KB

The EU Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (2011/65/EU = "RoHS 2") aims to exclude certain hazardous substances from electrical and electronic equipment or to restrict the use of certain substances in electrical and electronic equipment. These include substances such as lead, mercury, cadmium, and chromium, as well as certain brominated flame retardants and plasticizers. These substances may only be used in electrical and electronic equipment up to a maximum concentration limit, unless exemptions in the annexes to the directive permit their use under certain conditions. This can reduce and eliminate harmful substances and improve the recycling of waste electrical and electronic equipment. To find out whether the component you purchased from us is permitted in your device, please refer to the current directive or the current law applicable to your country. If you are a manufacturer, please feel free to contact us to find out whether the component you require can be tested and approved according to the current directives. We would be happy to assist you.

Fact sheet on EU Directive 2011/65/EU
Restriction of the use of hazardous substances in electrical and electronic equipment (PDF, not accessible, 2 MB)

Implementation of the RoHS Directive:
https://environment.ec.europa.eu/topics/waste-and-recycling/rohs-directive/implementation-rohs-directive_en

Source: IHK Mittelfranken

This product is: RoHS konform

Tariff Number: 85043180