Customised transformer
We are pleased to be able to offer and supply you with toroidal transformers made in Germany to your own specifications.
Please provide us with the following information:
- Primary voltage: our standard 230Volt 50Hz applies without specification
- Secondary voltages: We require both the voltage [Volt] and the current [Ampere]
- You can also specify several voltages or transformer taps, for example 350Volt-300Volt-0Volt-300Volt-350Volt with 0, 3Ampere
- You can specify a shield winding
- Please specify the maximum possible height
- Please specify the maximum possible diameter
- Please specify the desired quantity (important for the calculation)
- Please specify whether you want standard (with hole), with centre potting (central fixing) or potted in the cup (central fixing).
- Please specify whether you require standard or low leakage (low surcharge, but larger)
Please note:
- With tube amplifiers, it is advisable to slightly over-dimension the total power (10% to 20%), as these usually run in a very warm environment and could otherwise become very hot.
- The specified secondary voltage refers to the desired rated current; if this is lower, the voltage output is higher (for no-load operation and very low currents 10% to 30%, otherwise approx. 3% to 10%)
- If you wish to connect windings in parallel, please specify this separately
- For two-way rectification or tube rectification, desired double voltages e.g. 400V-0-400V can be used. e.g. 400V-0-400V cannot be connected directly in parallel (as they are connected in series).
These are connected together via the rectification
- The maximum secondary voltage per winding is 450Volt (reason is the insulation strength)
- The maximum secondary power with 1 phase is 1500VA
- Lowest possible secondary voltage: 4Volt (for low voltages below 10V, some tolerance must be taken into account due to the whole number of windings)
- The connections are made with stranded wires, approx. 20cm long
- Please note the fuse protection (slow-blow) for the inrush current. We recommend a soft-start circuit from 400VA
- We manufacture in accordance with the current legal requirements of the EU (RoHs, Reach, EN) VDE, CSA or UL approvals must, if required, be carried out by the customer himself
- We assume no liability for consequential damages or errors. Our general terms and conditions apply, see https://btb-elektronik. de/widerruf-agb/
- Customised toroidal transformers are calculated, calculated and manufactured especially for you (also single pieces), payment only by prepayment, no return possible
- Order must be made in writing (mail, contact via the shop, fax or by post)
- Standard delivery time from payment is two to four weeks
- Guarantee: 6 months from date of delivery
You can reach us by mail or phone:
info@btb-elektronik.de
+49 911 288585
We look forward to your enquiry and will offer you your desired transformer within a short time.
Your BTB Team, Michael Kaim