Lundahl LL2741 – 250 VA C-core mains transformer with a flexible high-voltage secondary

The Lundahl LL2741 is a C-core mains transformer for valve amplifiers. It combines a substantial high-voltage secondary with four separate 6.3 V heater windings, supporting several galvanically isolated heater circuits.

The high-voltage secondary consists of two equal sections. They can provide 290 V in series, approximately 145-0-145 V with a centre tap or 145 V with twice the current capability when correctly connected in parallel.

Suitable applications

  • Bridge-rectified valve-amplifier supplies using 290 V AC
  • Centre-tapped full-wave rectification from approximately 145-0-145 V
  • Lower-voltage, higher-current supplies using 145 V AC from parallel windings
  • Mono and stereo amplifiers requiring several separate heater circuits
  • Power supplies for low-impedance, high-current valves such as the 6C33C-B after complete power-budget calculation
  • AC or following DC heater supplies for preamplifier, driver and output valves

Technical data

Product type
C-core mains transformer for valve amplifiers
Model
LL2741
Total rating
Approx. 250 VA shared by all secondary windings
Primary connection for 230 V
Two primary windings connected in phase and in series
Primary connection for 115 V
Two primary windings connected in phase and in parallel
Primary DC resistance in series
Approx. 7.5 Ω
Primary DC resistance in parallel
Approx. 1.9 Ω
Main secondary in series
290 V AC no-load at 0.55 A maximum recommended RMS current
Main secondary with centre tap
Approximately 145-0-145 V AC at 0.55 A maximum recommended RMS current
Main secondary in parallel
145 V AC at 1.1 A maximum recommended RMS current with correct winding phase
DC resistance of the complete high-voltage secondary
Approx. 16 Ω
Heater windings
Four separate windings, each providing 6.3 V AC no-load
Maximum recommended current per heater winding
3.1 A RMS within the shared 250 VA power budget
DC resistance per heater winding
Approx. 0.1 Ω
Calculated power per heater winding
Approx. 19.5 VA at 6.3 V and 3.1 A
Calculated power of all four heater windings
Approx. 78.1 VA when fully loaded
Rectifier guidance with capacitor input
The manufacturer indicates approximately 63% of the stated AC RMS current as a DC-current guide before applying the complete power budget
Rectifier guidance with choke input
The manufacturer indicates approximately 95% of the stated AC RMS current as a DC-current guide before applying the complete power budget
Core
Lundahl C-core with a small balancing air gap to resist mains DC imbalance
Magnetic stray field
Particularly low when loads are distributed as evenly as practical between both coils
Dimensions
Approx. 118 × 85 × 78 mm
Mounting pattern
Approx. 53 × 90 mm with four M4 mounting points
Weight
Approx. 2.5 kg
Country of origin
Sweden

Power budgeting and rectification

The 290 V/0.55 A and four 6.3 V/3.1 A figures are winding ratings within one shared total. Fully loading all four heater windings uses approximately 78 VA and leaves correspondingly less capacity for the high-voltage circuit and transformer losses.

A 290 V/0.55 A load represents approximately 160 VA. Combined with four fully loaded heater windings, the calculated total is about 238 VA and therefore already close to the 250 VA design budget.

All listed voltages are no-load values. Loaded voltage depends on mains voltage, winding resistance, rectifier topology and current draw. Measure the heater and plate supplies in the completed amplifier under real load.

Safety notes

The primary and high-voltage secondary carry immediately lethal voltages. Provide suitable primary fusing, double-pole isolation, protective earth, strain relief and complete touch protection.

The chassis must safely support the 2.5 kg transformer and transport shock. Thin chassis material can require a reinforcing plate and large washers.

Questions about selection and use

Is the Lundahl LL2741 suitable for a bridge-rectified valve supply using 290 V AC?

Yes, the Lundahl LL2741 provides 290 V AC at up to 0.55 A recommended RMS current with its high-voltage sections in series. The rectifier, filter, required B+ voltage and complete 250 VA power budget must suit the circuit.

Can the LL2741 high-voltage winding also provide 145-0-145 V or 145 V/1.1 A?

Yes, the two equal sections can provide approximately 145-0-145 V with a centre tap or 145 V/1.1 A when connected in phase and in parallel. Incorrect phase in the parallel connection would short the windings.

Is the LL2741 suitable for four separate valve-heater circuits?

Yes, the LL2741 has four separate 6.3 V/3.1 A windings. Verify the actual heater voltage under the connected load, and keep all heater and high-voltage loads within the shared 250 VA rating.

Note: All brand names mentioned, such as Marshall, Fender, etc., are registered trademarks of their respective owners and are used here for descriptive and compatibility purposes only.

pdf
Title: ArLL2741_Netztr._LL2741_Lundahl_BTB_main_transformer.pdf Filesize: 233,61 KB
Responsible(EU)
Lundahl Transformers AB
SE-76150 Norrtälje
Email: order@lundahltransformers.com
pdf
Title: -EN-GPSR.pdf Filesize: 254,48 KB

The EU Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (2011/65/EU = "RoHS 2") aims to exclude certain hazardous substances from electrical and electronic equipment or to restrict the use of certain substances in electrical and electronic equipment. These include substances such as lead, mercury, cadmium, and chromium, as well as certain brominated flame retardants and plasticizers. These substances may only be used in electrical and electronic equipment up to a maximum concentration limit, unless exemptions in the annexes to the directive permit their use under certain conditions. This can reduce and eliminate harmful substances and improve the recycling of waste electrical and electronic equipment. To find out whether the component you purchased from us is permitted in your device, please refer to the current directive or the current law applicable to your country. If you are a manufacturer, please feel free to contact us to find out whether the component you require can be tested and approved according to the current directives. We would be happy to assist you.

Fact sheet on EU Directive 2011/65/EU
Restriction of the use of hazardous substances in electrical and electronic equipment (PDF, not accessible, 2 MB)

Implementation of the RoHS Directive:
https://environment.ec.europa.eu/topics/waste-and-recycling/rohs-directive/implementation-rohs-directive_en

Source: IHK Mittelfranken

This product is: RoHS konform

Tariff Number: 85043129

Country of Origin: SE